CTM CX-10HN – 10,000 BTU Condenser – Marine Split A/C Unit – 230V – 50/60HZ – R410A – NMEA 2000
The CTM CX-10HN condenser handles 10,000 BTU marine split A/C systems through 230V 50/60HZ power, R410A, and NMEA 2000.
- 10,000 BTU capacity suits compact zones.
- 230V supply requires compatible installation.
- 50/60HZ rating covers listed frequencies.
- R410A specifies the refrigerant type.
- NMEA 2000 supports networked control.
The smallest condenser in CTM’s NMEA 2000 lineup, the CX-10HN delivers 10,000 BTU of split-system cooling and heating on 230V power — a direct drop-in replacement for the Dometic DEG10 and DEU10 condensing units, sized for smaller cabins or as a secondary zone on a larger vessel.
Why Choose the CTM CX-10HN
This is CTM’s entry point into split-system cooling, useful for smaller cabins that don’t need 12,000+ BTU of capacity, or as an additional zone paired with a larger primary system on bigger boats. At 3.2A cooling draw, it’s also the lightest electrical load in CTM’s split condenser lineup.
Being a condenser-only unit, this pairs with a separately purchased evaporator in the cabin space — the CX and EV units share the same R410A refrigerant, so no evaporator swap is needed when only replacing a failed condenser on an existing CTM split system.
What to Know Before Installing
- EPA certification must be provided before shipping
- Requires a separately purchased evaporator — this listing is the condenser only
- If replacing a Cruisair RX unit, the evaporator will also need replacing due to the R22/R417A vs. R410A refrigerant difference
- Waterline connections use a standard 5/8″ fitting
Product Specifications
Product Specifications
| Brand | CTM Marine |
|---|---|
| Exact Model Code / SKU | CX-10HN (NMEA 2000 Version) |
| Country of Origin | USA |
| System Architecture | Split System Condenser |
| Cooling Capacity - BTU/h | 10,000 BTU/h |
| Cooling Capacity - kW/Watts | 2.93 kW |
| Heating Capacity - BTU/h | 10,000 BTU/h |
| Reverse Cycle Heating Function | Yes |
| Electrical Voltage | 230V |
| Alternating Current Frequency | 50/60 Hz |
| Electrical Phase | Single Phase |
| Full Load Amps - FLA Cooling | 3.2 A |
| Full Load Amps - FLA Heating | 4.2 A |
| Locked Rotor Amps - LRA | 11 A |
| Max Circuit Breaker Size | 15 A |
| Refrigerant Type | R-410A |
| Compressor Type | Hermetic Rotary |
| Seawater Water Flow Rate | 4.16 GPM (250 GPH) |
| Seawater Inlet Pipe Size | 5/8 inch (16 mm) |
| Seawater Outlet Pipe Size | 5/8 inch (16 mm) |
| Physical Dimensions - Unit | 8.67 x 13.5 x 13.5 inches (220 x 344 x 344 mm) |
| Net Weight | 35 lbs (16 kg) |
| Chassis & Condenser Material | Stainless Steel Pan & Titanium Coils |
| Standard Factory Warranty | 2 Years |
| Application & Sizing Guidance | Ideal for cabins up to 400 cu.ft, boat length 25-30 ft, integrated NMEA 2000 Gateway, min generator 2.5 kW. |