CTM Marine CT-6 6000 BTU Self-Contained Boat A/C
The CTM Marine CT-6 packages 6,000 BTU self-contained boat air conditioning for compact onboard spaces requiring an integrated unit.
- 6,000 BTU capacity suits smaller cabins.
- Self-contained design integrates operating components.
- Boat A/C targets onboard installations.
- CTM Marine CT-6 identifies model.
- Compact output fits limited interiors.
Small forward cabins and crew quarters usually benefit from equipment sized around the space rather than oversized salon capacity. The CTM Marine CT-6 delivers 6,000 BTU/h of cooling and 6,000 BTU/h of reverse-cycle heating from a 115V self-contained direct-expansion marine AC system. Its application guidance covers compact V-berths, aft crew quarters, and small cuddy cabins on boats measuring approximately 18 to 28 feet.
Who This Unit Is Not Ideal For
This unit is not suitable for 230V-only vessels, large salons, or spaces requiring more than 6,000 BTU/h. It may also be unsuitable where the available system cannot support the heating current or specified seawater flow. Actual sizing should consider cabin insulation and heat load.
Warranty and Product Summary
The supplied data does not specify a factory warranty for the CTM CT-6. This 115V self-contained system combines 6,000 BTU/h cooling and heating, digital display control, compact dimensions, and cupronickel condenser construction.
Product Specifications
Product Specifications
| Brand | CTM Marine |
|---|---|
| Full Model SKU/Code | CT-6-115V / 10034A (CT Series) |
| Country of Origin | USA |
| AC System Type | Self-Contained Direct-Expansion (DX) Marine AC |
| Cooling Capacity | 6,000 BTU/h (1.75 kW) |
| Heating Capacity | 6,000 BTU/h (Reverse Cycle Heat Pump Mode) |
| Refrigerant Type | R-410A Pre-Charged Eco-Friendly Gas |
| Compressor Technology | High-Efficiency Hermetic Rotary Compressor |
| Operating Voltage / Frequency | 115 Volts AC / 60 Hz Single Phase Base Rail |
| Full Load Amps / Running Current | Cooling Duty: 4.9 Amps / Heating Duty: 5.6 Amps |
| Locked Rotor Amps / Starting Current | 23.0 Amps LRA Base Threshold |
| Recommended Circuit Breaker Rating | 15 Amps Heavy-Duty Marine Breaker |
| Required Sea Water Flow Rate | 180 GPH / 11.4 Liters per minute minimum loop |
| Sea Water Inlet/Outlet Size | 5/8" (16mm) Outer Diameter Hose Barb Connections |
| Duct Display / Air Discharge Size | 4.0" (102mm) Rotatable High-Velocity Blower Collar |
| Condenser Coil Material | Corrosion-Resistant Cupronickel (CuNi 90/10) Coaxial Heat Exchanger Tube |
| Control Interface Connectivity | Digital Display Control Unit (RJ12 Connected Sync Controller Panel) |
| Dimensions (L x W x H) | 40.9 cm x 28.5 cm x 28.5 cm / 16.1" x 11.2" x 11.2" |
| Dry Weight | 18.1 kg / 40.0 lbs (Built on a corrosion-resistant lightweight stainless steel pan) |
| Application | Climate control routing for compact forward V-berths, standalone aft crew quarters, or small cuddy cabins (18-28 ft boat lengths) |